General

AMT SyncSys AxAMT SyncSys IO
DescriptionEthernet motion and I/O controllerEthernet I/O controller, no motion
Driver typeController only — STEP, DIR, ENABLE to external stepper or servo drives with step / direction input—
Axes3 (1- and 2-axis versions as OEM specials)None
Control modeHost command (ASCII over Ethernet)Host command (ASCII over Ethernet)

Power

Supply voltage15–30 Vdc, 24 Vdc nominalSame
Idle supply current80 mASame
Reverse-polarity protectionYesYes
Optional output+12 Vdc on main power connector pin 3Same

Motion

Step / pulse rate16 to 500,000 steps/s per axisFast channels F1–F3: 16 Hz to 500 kHz, clock or exact burst*
Axis modesPositioning, Feeder-Index, Spindle—
Motion profileTrapezoidal (linear ramp)—
Acceleration / deceleration1 to 10,000 ms, per axis—
Position counterSigned 32-bit—
HomingFast search, release, slow approach, clearance move—
Jog / continuousJog; continuous run in Spindle mode with speed change—
Motion typeCoordinated motion — not CNC interpolated motion. A multi-axis move line starts its axes together; no linear or circular interpolation—
Sync / position-compare outputs1 per axis (DO1 X, DO2 Y, DO3 Z)—
Non-volatile parametersYesYes

Digital & Analog I/O

Limit / home inputsLIM+ and LIM− per axis; LIM+ also HOME (normally closed, fail-safe)—
Digital inputs410
Digital outputs4 (DO1–DO3 also position-synchronized)13
IsolationDigital inputs, outputs and E-Stop opto-isolatedSame
Input voltage5–24 VdcSame
Output ratingsUser outputs: open collector, 48 V / 150 mA max. High-speed outputs: 5 V / 40 mASame circuits
E-StopNormally closed; gates every step output in hardwareNormally closed; stops the fast channels, holds the other outputs
Analog inputs2, 0–5 Vdc, 12-bit2, 0–5 Vdc, 12-bit

Communication

InterfaceEthernet 10/100Same
ProtocolPlain ASCII command set over TCPSame, without the axis commands
AddressIP address, factory default 192.168.1.222; field configurableSame
Firmware updateOver EthernetOver Ethernet
SoftwareAMT Script EngineAMT Script Engine

Protection & Status

Over-current / short-circuitYes (on-board DC-DC power supply)Same
Over-voltageYes, on the 5 Vdc driver-output supplySame
Under-voltageBrown-out reset and low-voltage detectionSame
Communications watchdogYesYes
Status reportingStatus and fault words, event messages over EthernetStatus, E-Stop state and event messages
IndicatorsStatus LEDStatus LED

Environmental & Mechanical

Operating temperature0 to 70 °CSame
Storage temperature−40 to 85 °CSame
Humidity5 to 95%, non-condensingSame
CoolingNatural convectionSame
Dimensions8.0 × 5.2 × 1.5 in (203 × 132 × 38 mm), without mating plugsSame
ConnectorsPluggable PTSM terminals: main power 6-position keyed; axis, user I/O and analog 6-position; limit inputs 3-position; supply inputs 2-position; Ethernet RJ45Same
IncludedMating PTSM plug connectorsSame

* Fast pulse channels are provided in a coming firmware release. Specifications are subject to change.