AMT SyncSys Ethernet Motion
& I/O Control
Software

Scripts a technician can read

A machine sequence is written as short, readable lines. The AMT Script Engine checks every line before it runs, shows the machine on screen while it runs, and speaks prompts to the operator.

The Script Engine
Load, check, run

The operator and runtime software. One edition runs a single controller or a machine of up to 2 motion and 4 I/O controllers.

  • Every line is checked before the script runs; a wrong command, axis, input, output or speed is listed with its line number and reason, and the script is not started
  • Machine status, jog and home, diagnostics and configuration screens
  • Spoken operator prompts, on-screen messages and a dated log of every part
  • Speeds, ramps and axis modes are set once on the Configuration screen, not in the script; positions are in millimetres
A complete cycle, 100 times✓ CHECKED
ENABLE,ALL,ONHOME,ALL,SEQSET,R1,0LABEL,CYCLEWAITIN,1,ONMOVE,X,150WAITMOVEOUTPUT,1,ONDWELLMS,500OUTPUT,1,OFFMOVE,X,0ADD,R1,1LOG,Part {R1} doneSPEAKLINE,Part completeIF,R1,<,100,GOTO,CYCLEEND
The Script Language
Plain commands, real program flow

Scripts also have registers, IF and LOOP, named routines (CALL), and can start another program on the PC (RUNPROGRAM) — so a sequence can count parts, branch on an input and hand data to other software.

HOME,ALL,SEQHome the axes in sequence
MOVE,X,150Move an axis to a position (mm)
WAITMOVEWait for motion to finish
WAITIN,1,ONWait for an input
OUTPUT,1,ONSwitch an output
DWELLMS,500Wait a set time (ms)
SET / ADDRegisters for counts and values
IF … GOTOBranch on a condition
LOOP / CALLRepeat and named routines
LOGDated log of every part
SPEAKLINESpoken operator prompt
RUNPROGRAMStart another program on the PC
The Toolset
Write it, see it, prove it

AMT Script Editor

Writes and checks scripts away from the machine, with a command list and line-by-line checking.

AMT Visualizer

Stands in for the controllers on the PC and shows the machine moving, including an isometric 3D view, so scripts can be tried without hardware.

AMT Test Runner

Automatic qualification of the software, with a Word report that says QUALIFIED when every item passes; witnessed tests record each answer.

Platforms & Displays
Runs on a panel, a PC, or both

Each platform has its own installation package that installs everything needed and creates desktop and menu icons.

Raspberry Pi 4 (64-bit Raspberry Pi OS) with a 10-inch touch displayMachine-mounted operator panel; the Small layout fits a 1024 × 600 touch screen
Windows 10 / 11 PCOffice or machine PC — script writing, Visualizer, operation
Linux Mint PCMachine or office PC

Two screen layouts

Large for 1920 × 1080 monitors and up; Small for 1024 × 600 touch screens.

Single or multiple monitors

The Script Engine, Script Editor and Visualizer are separate windows — for example, the operator screen on one monitor and the Visualizer on another.

Network

The PC or panel connects to the controllers over Ethernet. Each controller has its own address (factory default 192.168.1.222).

Open protocol: the controllers use plain ASCII commands over Ethernet, so they also work with a PLC or any PC program.

Discuss your machine.

Describe the sequence, the axes and the I/O. We'll confirm the configuration and provide a quotation.

Request a Quote →